AAPP V4.1 Update Release, 12/12/2003 *************************************************************************** The update release V4.1 of AAPP consists of a bug fix and an improvement of amsuacl and atovin to deal with the failing AMSU-A1 instrument on NOAA17. 1. Bug fix In AAPP V4.0 the serial number of MSU of NOAA14 differs from the expected value in the code. Copy msuhdu.F to .../decommutation/ replacing the faulty version and rebuild decommutation by running INST_4 with manual input: option 6 sub-option 12. 2. Improvement AAPP V4.0 is not able to calibrate AMSU-A data from NOAA17 since AMSU-A1 is failing to work. Three routines have been modified so that at least the AMSU-A2 data can be calibrated. Copy ama_antpos.F, ama_updt.F and ama_initcl.F to .../amsuacl/ and copy inaprc.F to .../atovin/ Rebuild amsuacl by running running INST_4 with manual input: option 6 sub-option 16 and rebuild atovin by running running INST_4 with manual input: option 6 sub-option 19. ***************************************************************************